Skip to content
MEDORAR
← VITAL360

VITAL360

CT scans

Use CT only with a medical indication. Radiation exposure and alternatives explained transparently.

AI-generated illustrative video – not an actual partner clinic
AI-generated illustrative video – not an actual partner clinic

Only with a medical indication

A CT scan uses X-rays. It makes sense when the expected benefit justifies the radiation. A doctor makes this judgement.

Offers

Fictional, quality-verified facilities with dose reports. Prices are prototype guide prices.

Sorted by facility name. No ranking by payment.

Klinik A / Bangkok

128-Zeilen-CT

from 260 €

Contrast agent: + 60 €

Examinations:
Thorax (Lunge), Abdomen, Herz (Koronar-CT)
Included:
Untersuchung, schriftlicher Befund (EN/TH), Bilder als DICOM, Dosisprotokoll
Languages:
en · th
Waiting time:
approx. 3 days

Niedrigdosis-Protokoll für Lungen-CT verfügbar

Quality VerifiedRe-audit by 30.06.2027

Klinik B / Istanbul

64-Zeilen-CT

from 190 €

Contrast agent: + 50 €

Examinations:
Kopf, Thorax (Lunge), Abdomen, Nasennebenhöhlen
Included:
Untersuchung, schriftlicher Befund (DE/TR/EN), Bilder als DICOM, Dosisprotokoll
Languages:
de · tr · en
Waiting time:
approx. 5 days

Quality VerifiedRe-audit by 31.03.2027

Klinik C / Berlin

Dual-Source-CT

from 410 €

Contrast agent: + 90 €

Examinations:
Kopf, Thorax (Lunge), Herz (Koronar-CT), Gefäße
Included:
Untersuchung, schriftlicher Befund (DE/EN), Bilder als DICOM, Dosisprotokoll, Befundgespräch
Languages:
de · en
Waiting time:
approx. 9 days

Dosisreduzierte Herz-CT-Protokolle

Quality VerifiedRe-audit by 30.09.2027

Radiation and alternatives

Rounded guide values for orientation. The actual dose depends on scanner, protocol and body size.

Röntgen Thorax0,05 mSvFlug Frankfurt – Bangkok (hin und zurück)0,1 mSvNiedrigdosis-CT Lunge1,5 mSvCT Kopf2 mSvNatürliche Strahlung pro Jahr (Deutschland)2,1 mSvCT Thorax5 mSvCT Abdomen8 mSv

Effective dose in millisieverts (mSv), rounded. Modern low-dose protocols may be lower. Ask for the dose report.

Alternatives with no or less radiation

MethodRadiationWell suited forLimits
UltraschallkeineBauchorgane, Schilddrüse, Gefäße, WeichteileLunge und Knochen kaum beurteilbar, abhängig von Untersucher
MRTkeineGehirn, Rückenmark, Gelenke, Weichteile, Leberlänger, laut, Einschränkungen bei Implantaten
RöntgengeringKnochenbrüche, Lunge (Übersicht)nur zweidimensional, wenig Weichteilkontrast
Abwarten und Verlaufskontrollekeineunklare, nicht dringliche Beschwerden nach ärztlicher Rücksprachenur wenn medizinisch vertretbar

Indication and appointment request

Demo request to a fictional facility. Nothing is sent.

Step 1 of 5: Indication

Has a doctor recommended this examination?

Imaging without a medical reason can lead to incidental findings, needless worry and further procedures.

In an emergency, call your local emergency number immediately (Germany and Türkiye 112, Thailand 1669). This platform is not meant for emergencies.

Image viewer (demo)

This is how you will see your images in MEDORAR later. The preview shows a synthetic phantom, not a real patient image.

CT head non-contrast, axial (phantom)

Slice 9 / 24

Tip: click the image or select it with Tab, then browse the slices with the arrow keys.

Window

DICOM metadata

(0010,0010)Name
PSEUDONYM^7F3A
(0010,0030)Date of birth
removed
(0008,0080)Institution
Klinik A / Bangkok (fiktiv)
(0008,0020)Study date
20261002
(0008,0060)Modality
CT
(0008,103E)Series
CT head non-contrast, axial (phantom)
(0018,0050)Slice thickness
5 mm
(0028,0030)Pixel spacing
0.9 \ 0.9 mm
(0028,0010)Matrix
256 × 256

Before sharing, MEDORAR removes name and date of birth from the metadata. Measurements in the preview are for orientation only and do not replace a radiological report.

Upload images (DICOM)

Upload images from a previous examination to share them with specialists later.

Drag files here

DICOM (.dcm or no extension), ZIP archive of a CD/DVD, report as PDF

Prototype: only file name, size and date are shown. The content is not read or transferred. In production, images would be pseudonymised and scanned for malware before sharing.

Report comparison

Two synthetic reports side by side, older on the left. You and your doctor see changes at a glance.

14.10.2025

MRT Lendenwirbelsäule

Klinik C / Berlin

02.10.2026

MRT Lendenwirbelsäule

Klinik B / Istanbul

LWK 4/5

changed

Bandscheibenvorwölbung, mediolateral links (4 mm)

Bandscheibenvorwölbung, mediolateral links, rückläufig (3 mm)

LWK 5/SWK 1

unchanged

Leichte Chondrose, kein Bandscheibenvorfall

Leichte Chondrose, kein Bandscheibenvorfall

Spinalkanal

unchanged

Normal weit

Normal weit

Nervenwurzel L5 links

changed

Fraglicher Kontakt

Kein Kontakt mehr abgrenzbar

Iliosakralgelenke

newly described

–

Unauffällig

Impression: Bandscheibenvorwölbung LWK 4/5 links mit fraglichem Kontakt zur Wurzel L5.

Impression: Rückläufige Bandscheibenvorwölbung LWK 4/5 ohne Wurzelkontakt. Keine neue Pathologie.

The comparison only matches text sections. It does not replace a medical assessment. Different scanners and facilities can explain differences.